Johanniter-Krankenhaus Geesthacht GmbH

Quality results

Treatment sector: Defibrillator (shock generator) for the treatment of cardiac arrhythmias: first implantation (09/4) Explanation

Designation Implantierbare Defibrillatoren - Implantation
Shortcut 09/4
Number of cases 6
Documentation rate 100 %
Hospital comment Die Dokumentationsrate wurde krankenhausbezogen berechnet.

Summary result:

In 10 of 10 quality characteristics, the quality objective was achieved.
No assessment is possible for any quality characteristic


Number of patients treated: 6

Quality objective achieved
Quality objective not achieved

The results in detail

Quality criterion
Hospital result
and target area
Quality objective
achieved?
All information
Treatment with a shock generator (defibrillator) was appropriate according to scientific standards
Hospital: 100,00 %
Target area: at least 90,00 %
Quality objective achieved
The shock generator (defibrillator system) was selected on the basis of recognised scientific recommendations
Hospital: 100,00 %
Target area: at least 90,00 %
Quality objective achieved
Duration of the operation during which the shock generator (defibrillator) is first used or the housing is replaced
Hospital: 100,00 %
Target area: at least 60,00 %
Quality objective achieved
Hospital: 0,00
Target area: at most 2,72
Quality objective achieved
Various measurements during the operation showed that the shock generator’s (defibrillator’s) wiring was functioning properly
Hospital: 83,33 %
Target area: at least 90,00 %
Quality objective achieved
Why?
Hospital: 0,00 %
Target area: at most 2,50 %
Quality objective achieved
Unwanted changes in position or malfunction of the shock generator’s (defibrillator's) wires
Hospital: 0,00 %
Target area: at most 3,00 %
Quality objective achieved
Hospital: 100,00 %
Evaluation is not available
Ratio of the actual number to the previously expected number of patients who died during their hospital stay (the individual risks of the patients were taken into account)
Hospital: 0,00
Target area: at most 6,96
Quality objective achieved
Ratio of actual to expected number of patients who experienced tube or pouch problems related to the insertion of a shock generator and resulted in a repeat surgery within one year.
Hospital: Data protection

No information due to data protection

as rarely as possible
Quality objective achieved
Ratio of actual to expected number of patients who had infections or perforations of the casing through the skin associated with the insertion of a shock generator, leading to a repeat operation within one year.
Hospital: Data protection

No information due to data protection

as rarely as possible
Quality objective achieved